CVE ID | CVE-2025-5825 |
CVSS SCORE | 7.5, AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H |
AFFECTED VENDORS |
Autel |
AFFECTED PRODUCTS |
Autel MaxiCharger AC Wallbox Commercial |
VULNERABILITY DETAILS |
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability. The specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. |
ADDITIONAL DETAILS |
Fixed in American Standard: V1.39.51 and European Standard: V1.56.51 |
DISCLOSURE TIMELINE |
|
CREDIT | Sina Kheirkhah (@SinSinology) of Summoning Team (@SummoningTeam) |