CVE ID | CVE-2025-5828 |
CVSS SCORE | 6.8, AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
AFFECTED VENDORS |
Autel |
AFFECTED PRODUCTS |
Autel MaxiCharger AC Wallbox Commercial |
VULNERABILITY DETAILS |
This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of USB frame packets. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length buffer. An attacker can leverage this vulnerability to execute code in the context of the device. |
ADDITIONAL DETAILS |
Fixed in American Standard: V1.39.51 and European Standard: V1.56.51 |
DISCLOSURE TIMELINE |
|