| CVE ID | CVE-2014-5424 |
| CVSS SCORE | 7.5, AV:N/AC:L/Au:N/C:P/I:P/A:P |
| AFFECTED VENDORS |
Rockwell Automation |
| AFFECTED PRODUCTS |
Connected Components Workbench |
| TREND MICRO CUSTOMER PROTECTION | Trend Micro TippingPoint IPS customers are protected against this vulnerability by Digital Vaccine protection filter ID ['16532']. For further product information on the TippingPoint IPS: http://www.tippingpoint.com |
| VULNERABILITY DETAILS |
The specific flaw exists within the RA.ViewElements.Grid.1 ActiveXControl method. By providing a malicious value to the LeftXOffset property, an attacker can write a four byte null value to an arbitrary location. An attacker could use this to execute arbitrary code in the context of the browser.
|
| ADDITIONAL DETAILS |
Rockwell Automation has issued an update to correct this vulnerability. More details can be found at:
https://ics-cert.us-cert.gov/advisories/ICSA-14-294-01 |
| DISCLOSURE TIMELINE |
|
| CREDIT | Andrea Micalizzi (rgod) |