CVE ID | CVE-2025-9275 |
CVSS SCORE | 7.8, AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
AFFECTED VENDORS |
Oxford Instruments |
AFFECTED PRODUCTS |
Imaris Viewer |
VULNERABILITY DETAILS |
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Oxford Instruments Imaris Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of IMS files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated data structure. An attacker can leverage this vulnerability to execute code in the context of the current process. |
ADDITIONAL DETAILS |
07/14/25 - ZDI reported the vulnerability to the vendor’s security team -- Mitigation: Given the nature of the vulnerability, the only salient mitigation strategy is to restrict interaction with the product. |
DISCLOSURE TIMELINE |
|
CREDIT | rgod |