Advisory Details

June 11th, 2013

Hewlett-Packard Data Protector Cell Manager crs.exe Opcode 259 Remote Code Execution Vulnerability

ZDI-13-126
ZDI-CAN-1637

CVE ID CVE-2013-2329
CVSS SCORE 10.0, AV:N/AC:L/Au:N/C:C/I:C/A:C
AFFECTED VENDORS Hewlett-Packard
AFFECTED PRODUCTS Data Protector
TREND MICRO CUSTOMER PROTECTION Trend Micro TippingPoint IPS customers are protected against this vulnerability by Digital Vaccine protection filter ID ['10055']. For further product information on the TippingPoint IPS: http://www.tippingpoint.com
VULNERABILITY DETAILS


This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of HP Data Protector. Authentication is not required to exploit this vulnerability.

The specific flaw exists within crs.exe which listens by default on a random TCP port. When parsing opcode 259, the process blindly copies user supplied data into a fixed-length stack buffer. A remote attacker can abuse this to execute remote code under the context of the SYSTEM user.

ADDITIONAL DETAILS Hewlett-Packard has issued an update to correct this vulnerability. More details can be found at:
https://h20566.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03781657
DISCLOSURE TIMELINE
  • 2012-12-04 - Vulnerability reported to vendor
  • 2013-06-11 - Coordinated public release of advisory
CREDIT e6af8de8b1d4b2b6d5ba2610cbf9cd38
BACK TO ADVISORIES