| CVE ID | CVE-2015-8561 |
| CVSS SCORE | 6.8, AV:N/AC:M/Au:N/C:P/I:P/A:P |
| AFFECTED VENDORS |
Schneider Electric |
| AFFECTED PRODUCTS |
ProClima |
| TREND MICRO CUSTOMER PROTECTION | Trend Micro TippingPoint IPS customers are protected against this vulnerability by Digital Vaccine protection filter ID ['20649']. For further product information on the TippingPoint IPS: http://www.tippingpoint.com |
| VULNERABILITY DETAILS |
The specific flaw exists within the implementation of the AttachToSS method of the F1BookView ActiveX control. The method accepts an integer value and interprets it as the address of a structure in memory. An attacker can leverage this vulnerability to achieve code execution in the context of the process. |
| ADDITIONAL DETAILS |
Schneider Electric has issued an update to correct this vulnerability. More details can be found at:
https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02 |
| DISCLOSURE TIMELINE |
|
| CREDIT | Ariele Caltabiano (kimiya) |