Advisory Details

April 11th, 2018

OMRON CX-One CX-Motion sscanf Stack-based Buffer Overflow Vulnerability

ZDI-18-281
ZDI-CAN-5402

CVE ID CVE-2018-7514
CVSS SCORE 6.8, AV:N/AC:M/Au:N/C:P/I:P/A:P
AFFECTED VENDORS OMRON
AFFECTED PRODUCTS CX-One
VULNERABILITY DETAILS


This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of OMRON CX-One. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.

The specific flaw exists within the processing of MCI files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code under the context of the current process.

ADDITIONAL DETAILS OMRON has issued an update to correct this vulnerability. More details can be found at:
https://ics-cert.us-cert.gov/advisories/ICSA-18-100-02
DISCLOSURE TIMELINE
  • 2017-12-01 - Vulnerability reported to vendor
  • 2018-04-11 - Coordinated public release of advisory
  • 2018-04-11 - Advisory Updated
CREDIT rgod